Modular LivingAustralia

Main page › Guides › Class 2 apartments

Modular apartments and Class 2 buildings

This page describes NCC 2022 Volume One as published by the ABCB. States and territories adopt and vary the code on their own timetables, and a building surveyor or certifier decides what applies to a specific project. Nothing here is compliance advice.
Class 2 at a glance
What Class 2 isAn apartment building of sole-occupancy units with people living above and below each other[1]
Code volumeNCC Volume One (Classes 2 to 9)[1]
Construction type, 3+ storeysType A[2]
Unit-to-unit airborne sound (deemed-to-satisfy)Rw + Ctr of at least 50 for walls and floors[3]
Floor impact sound (deemed-to-satisfy)Ln,w no more than 62[3]

A Class 2 building is an apartment building: separate homes, called sole-occupancy units, with people living above and below each other.[1] Moving from a house to this class changes the code volume and brings in fire and sound requirements designed for stacked homes. The same classification applies whether the building is built on site or assembled from factory-built modules; the class follows the use, not the construction method.

Where Class 2 sits in the code §

Class 2 belongs to NCC Volume One, which covers Classes 2 to 9, rather than Volume Two, which covers houses.[1] For how Class 2 compares with Class 1 and Class 3, see building classes for shared housing. Shared-living uses such as student residences generally fall in Class 3; see modular student accommodation.

Fire: type of construction and fire-resistance levels §

The NCC ties the required type of fire-resisting construction (A, B or C) to the number of storeys.

Rise in storeysConstruction typeException
3 or moreType A[2]None stated
2Type B[2]Type C with two exits per unit[2]
1Type C[2]None stated

The exception for two storeys applies where each unit has at least two exits or its own direct access to a road or open space.[2]

Each type then sets fire-resistance levels (FRLs) for building elements. FRLs are written as three numbers in minutes: structural adequacy, integrity and insulation.[4]

ElementTypeFRL
Loadbearing walls between unitsA90/90/90[4]
Loadbearing walls between unitsB60/60/60[4]
Internal walls between unitsC60/60/60[4]
FloorsA90/90/90[4]

Separately, a floor dividing storeys in a Class 2 building (other than inside one unit) needs at least 30/30/30 or an acceptable fire-protective covering.[4] These figures are the deemed-to-satisfy route; a performance solution that meets the performance requirements does not need to follow them.[4] Low-rise concessions exist that allow timber framing in some Class 2 buildings when sprinklers and other conditions are met; see timber framing and engineered wood and steel framing in prefab homes for the materials themselves.[4]

Sprinklers §

A dedicated specification sets sprinkler requirements for Class 2 and 3 buildings of four or more storeys and up to 25 m in effective height. It names the accepted sprinkler standards, adds provisions for larger systems, and gives design concessions where a sprinkler system is installed.[5]

Sound between apartments §

Part F7 limits sound passing between units and from common areas into units. It does not deal with noise from outside the building.[3]

ElementMeasureDeemed-to-satisfy value
Wall between unitsAirborne soundRw + Ctr of at least 50[3]
Floor between unitsAirborne soundRw + Ctr of at least 50[3]
Floor between unitsImpact soundLn,w of no more than 62[3]

The performance requirement uses a lower airborne figure (DnT,w + Ctr of at least 45) because it is measured on site rather than in a laboratory.[3] Walls between a wet area or kitchen in one unit and a habitable room in the next also need to limit impact sound; the deemed-to-satisfy route is a two-leaf wall with at least a 20 mm cavity.[3] Compliance can be shown from laboratory ratings or, under the verification methods, from testing in the finished building.[3]

What is not covered here §

This page does not cover other Class 2 requirements such as egress and exits, accessibility, energy efficiency, fire-fighting services beyond sprinklers, or fire hazard properties of materials.

It is based on NCC 2022 Volume One. Whether NCC 2025 changed any of these provisions, and how each state or territory varies the code, is not covered by sources compiled here; for the edition timetable see NCC 2025 and new homes. Transport, crane and module-connection engineering, and factory certification pathways, are not covered by sources compiled here (see Australian standards for prefab buildings for standards).

Planning rules, apartment design guides and costs are not covered. Nothing here classifies or assesses a particular building.

Ask Modular Living AI about this guide

Still have a question after reading this guide? Ask it here. The answer draws on this guide, our other guides and the official pages they cite, with links to each one it used.

General information only, not legal, financial or building advice.

The Dispatch — a monthly email when new guides are published. No noise; unsubscribe anytime.

Sent to info@modularlivingaustralia.com.au and handled by a person. See Privacy.

References §

  1. Australian Building Codes Board — NCC Navigator, building classifications — Class 2 is an apartment building made up of sole-occupancy units where people live above and below each other. Classes 2 to 9 are in Volume One of the NCC. nccb.gov.au/ncc-navigator/building-classifications
  2. Australian Building Codes Board — NCC 2022 Volume One, Part C2 Fire resistance and stability — Required type of construction for Class 2 by rise in storeys: three or more storeys Type A; two storeys Type B; one storey Type C. A two-storey Class 2 building can be Type C if each sole-occupancy unit has two exits or its own direct access to a road or open space (C2D6). ncc.abcb.gov.au/editions/ncc-2022/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability
  3. Australian Building Codes Board — NCC 2022 Volume One, Part F7 Sound transmission and insulation — Walls and floors between sole-occupancy units: performance DnT,w + Ctr at least 45; deemed-to-satisfy Rw + Ctr at least 50. Floor impact: performance LnT,w not more than 62; deemed-to-satisfy Ln,w not more than 62. Walls between a wet area or kitchen and a habitable room in an adjoining unit need discontinuous construction (at least 20 mm cavity) in the deemed-to-satisfy route. Verification methods F7V1 and F7V2 use in-situ testing. Does not cover sound from outside the building. ncc.abcb.gov.au/editions/ncc-2022/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation
  4. Australian Building Codes Board — NCC 2022 Volume One, Specification 5 Fire-resisting construction — Fire-resistance levels (FRLs) are written as structural adequacy/integrity/insulation in minutes. For Class 2 Type A, loadbearing internal walls bounding or between sole-occupancy units are 90/90/90 and floors 90/90/90; Type B loadbearing walls between units are 60/60/60; Type C internal walls between units are 60/60/60. Floors separating storeys in Class 2 need at least 30/30/30 or an acceptable fire-protective covering. Concessions S5C20 and S5C23 allow timber framing in certain low-rise Class 2 and 3 buildings if sprinklers and other conditions are met. The specification applies to deemed-to-satisfy provisions only. ncc.abcb.gov.au/editions/ncc-2022/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction
  5. Australian Building Codes Board — NCC 2022 Volume One, Specification 18 Class 2 and 3 buildings not more than 25 m in effective height — Sets sprinkler requirements for Class 2 and 3 buildings up to 25 m in effective height with four or more storeys: accepted standards (AS 2118.1, AS 2118.4, FPAA101D, FPAA101H), extra provisions for larger systems and occupant numbers, alarm measures and design concessions where sprinklers are installed. ncc.abcb.gov.au/editions/ncc-2022/adopted/volume-one/e-services-and-equipment/18-class-2-and-3-buildings-not-more-25-m-effective-height

Figures are as published by the sources above at their respective dates and are paraphrased summaries, not verbatim reproductions. Verify current pricing and rules directly with builders, lenders and planning authorities.